Version 2/24/2014 INSTALLATION, OPERATION & MAINTENANCE MANUAL FARHENHEIT™ KZN(R)-F SERIES HEAVY DUTY AGITATOR TOP DISCHARGE Electric Submersib
10 TYPICAL AUTOMATIC DEWATERING INSTALLATION NOTE: Maximum recommended starts should not exceed 10 times per hour. Three phase pumps need a se
11 INTENDED METHODS OF CONNECTION Use with approved motor control that matches motor input in full load amperes. “UTILLISER UN DÉMARREAR APPR
12 To automatically operate a non-automatic three phase pump, a control panel is required. UFollow the instructions provided with th
13 SERVICING YOUR SUBMERSIBLE PUMP Pump should be disconnected from the electric power supply before proceeding to do any service or maintenance. To
14 CHANGING SEALS* 1) Make sure that the pump cable is disconnected from the power source. 2) Lay the pump down on its side. 3) Remove the oil i
15 EXPLODED VIEW OF KZN37-F, 55-F, 55R-F, 55CH-F, 55CHR-F, 75-F, 75R-F
16 EXPLODED VIEW OF KZN110-F, 110R-F, 110H-F, 110HR-F, 150-F, 150R-F, 150L-F, 150LR-F
17 EXPLODED VIEW OF KZN220-F, 220R-F, 220L-F, 220LR-F
18 KZN-F SERIES PARTS LIST Pump Model KZN37F KZN55F KZN55CHF KZN75F KZN110F KZN110HF KZN150F KZN150LF KZN220F KZN220LFPos. No. Part Description Item
19 27-1 O-Ring (Kit Only) Kit Kit Kit Kit Kit Kit Kit Kit Kit Kit27-2 Power Cord Housing 202490 202490 202490 202490 202493 202493 202493 202493 292
20 KZNRF PARTS LIST Pump Model KZN37RF KZN55RF KZN55CHRF KZN75RF KZN110RF KZN110HRF KZN150RF KZN150LRF KZN220RF KZN220LRFPos. No. Part Description It
21 27-1 O-Ring (Kit Only) Kit Kit Kit Kit Kit Kit Kit Kit Kit Kit27-2 Power Cord Housing 202490 202490 202490 202490 202493 202493 202493 202493 292
22 THREE PHASE WIRING DIAGRAMS 208V MODELS KZN37-F, 37R-F, 55-F, 55CH-F, 55R-F, 55CHR-F
23 230V MODELS KZN37-F, 37R-F, 55-F, 55CH-F, 55R-F, 55CHR-F, 75-F, 75R-F, 110-F, 110H-F, 110R-F, 110HR-F
24 460V MODELS KZN37-F, 37R-F, 55-F, 55R-F, 55CHR-F, 75-F, 75R-F, 110-F, 110H-F, 110HR-F, 150-F, 150L-F, 150L-F, 150LR-F, 150R-F, 220-F, 220L-F, 22
25 575V MODELS KZN37-F, 37R-F, 55-F, 55R-F, 55CHR-F, 75-F, 75R-F, 110-F, 110H-F, 110HR-F, 150-F, 150L-F, 150L-F, 150LR-F, 150R-F, 220-F, 220L-F, 2
26 SEAL MINDER® - THERMAL MOTOR SENSOR SWITCH (For high temperature pump models) Seal Minder: Also known as a seal failure circuit (or moisture det
28 BJM Pumps, LLC 123 Spencer Plain Road Old Saybrook, CT 06475, U.S.A. WARRANTY AND LIMITATION OF LIABILITY Unless otherwise expressly authoriz
START-UP REPORT FORM START-UP REPORT FORM This form is designed to record the initial installation, and to serve as a guide for troubleshooting at a
TABLE OF CONTENTS INTRODUCTION ...
START-UP REPORT FORM presence? Are guide rails exactly vertical? Yes No Is base elbow installed level? Yes No Liquid level controls: Model Is
START-UP REPORT FORM Voltage supply at panel line connection, pump on L1-L2 L2-L3 L3-L1 Amperage load connection, pump on L1 L2 L3 FINAL CHECK Is p
NOTES:
FARHENHEIT™ is a trademark of BJM Pumps, LLC. BJM Pumps & Seal Minder is a registered trademark of BJM Pumps, LLC Copyright © 2009-2013 BJM Pum
4 INTRODUCTION This Installation, Operation and Maintenance manual provides important information on safety and the proper inspection, disassem
5 SAFETY Pump installations are seldom identical. Each installation and application can vary due to many different factors. It is the owner/s
6 INSPECTION Review all safety information before servicing pump. The following are recommended installation practices/procedures for the pump. If t
7 ½”, and that will be above the upper bearing. Do not overfill, an air gap of 10-15% must be maintained for heat expansion. PUMP INSTALLATION KZN-F
8 PUMP ROTATION Two ways to check the correct pump rotation: 1. By looking at the impeller; the rotation of the impeller should be counter clockw
9 PUMP OPERATION This pump is designed to handle dirty water that contains some solids. It is not designed to pump volatile or flammable liquids