Bjm-pumps JX1500HSS-F Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 29
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
10
PUMP OPERATION
This pump is designed to handle dirty water that contains some
solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump
any liquids which may damage the pump or endanger personnel as a result of pump
failure.
Do not operate this pump where explosive vapors or
flammable material exist. Death or Serious injury may result.
NOTE: Maximum recommended starts should not exceed 10 times per hour.
All J-F & JX-F models are provided with a 50’ (15m) power cable. NEVERUU splice the
power cable due to safety and warranty considerations. Always keep the lead end dry.
Note: The single phase 115V and 230V high temperature pumps are designed to be
connected directly to a proper pump control and cannot be directly plugged into a power
outlet.
Do not alter the length or repair any power cable with a splice. The
pump motor and cable must be completely waterproof. Damage to the pump or
personal injury may result from alterations.
The BJM Pumps, J-F and JX-F series pumps require a special control that contains the
starting components, thermal sensor and Seal Minder connections. These pumps
cannot be directly connected to a power source.
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 28 29

Commentaires sur ces manuels

Pas de commentaire